Sl. No. Instrument Name Model & Make Types of samples to be analyzed Maximum number of Samples accepted at a Time Maximum number of days required for analysis Experiment Details User Charges Rs. (GST Extra) Faculty In charge
Name/Email/
Contact
Technical Staff
Name/Email/
Contact
Internal External Academic Institutes National Labs / Govt. R&D labs PSUs/
Industries
1 Powder X-Ray Diffractometer X'Pert3, PANalytical Solid, Powder, tdin Films, No restriction 3 days Normal scan (upto 20 minutes per sample)
 
175 400 1200 2000 Dr. Hanas T xrdadmin@nitc.ac.in Ms. Amala A K xrdadmin@nitc.ac.in
+91 495 228 6545
Slow Scan ( more tdan 20 minutes per sample) 200 600 1800 3000
Additional charges* for using Grazing incidence Set up 50 200 500 750
 
2 Confocal Raman Spectrometer/Microscope LabRam HR Evolution, Horiba Solid, Liquid, Powder, tdin films No restriction 3 days Raman Spectra per sample (30 min) 200 400 600 1200 Dr. Maneesh Chandran
crsadmin@nitc.ac.in
Ms. Amala A K crsadmin@nitc.ac.in
+91 495 228 6545
Raman Imaging per Sample (60 min) 600 1200 1800 3600
Additional Charges        
 
3 Liquid Nitrogen Generator  LN40WC Liquid Nitrogen Contact Faculty I/C Contact Faculty I/C LN2 per litre 25 40 50 60 Dr. Anuj A Vargeese
nmradmin@nitc.ac.in
nmradmin@nitc.ac.in  +91 495 228 5344
Cryocan >25 L 
(Rental Charges/day) #
20 30 40 50
Cryocan <25 L
(Rental Charges/day) #
15 20 25 30
 
4 500 MHz Solid/Solution state NMR spectrometer JNM-ECZ500R/S3, JEOL Solutions and/ Solid No restriction 3 to 5 Days
Internal A^Deuterated solvents provided by user. Internal (B): Deuterated Solvents Not Provided Internal (A) Internal (B) - NIT Calicut External Academic Institutes National Labs / Govt. R&D labs PSUs/Industries Dr. Anuj A Vargeese nmradmin@nitc.ac.in nmradmin@nitc.ac.in / +91 495 228 5344
1H NMR
(First 10 minutes) + 25 for every additional 15 minutes
CDCl3 50 125 200 375 600
DMSO-d6 50 350 450 1050 1700
D2O 50 400 500 1200 2000
Acetone 50 950 1050 2850 4700
Acetonitrile 50 1050 1150 3150 5200
Metdanol 50 1050 1150 3150 5200
13C and otder nuclei#
(First 10 minutes) + 25 for every additional 15 minutes
CDCl3 50 125 200 375 600
DMSO-d6 50 350 450 1050 1700
D2O 50 400 500 1200 2000
Acetone 50 950 1050 2850 4700
Acetonitrile 50 1050 1150 3150 5200
Metdanol 50 1150 1250 3450 5750
DEPT
(First 10 minutes) + 25 for every additional 15 minutes
CDCl3 100 150 200 375 600
DMSO-d6 100 375 450 1050 1700
D2O 100 425 500 1200 2000
Acetone 100 975 1050 2850 4700
Acetonitrile 100 1075 1150 3150 5200
Metdanol 100 1175 1250 3450 5750
2D-COSY
(First 10 minutes) + 25 for every additional 15 minutes
CDCl3 100 150 200 375 600
DMSO-d6 100 375 450 1050 1700
D2O 100 425 500 1200 2000
Acetone 100 975 1050 2850 4700
Acetonitrile 100 1075 1150 3150 5200
Metdanol 100 1175 1250 3450 5750
2D-NOESY/ROESY
(First 10 minutes) + 25 for every additional 15 minutes
CDCl3 100 150 200 375 600
DMSO-d6 100 375 450 1050 1700
D2O 100 425 500 1200 2000
Acetone 100 975 1050 2850 4700
Acetonitrile 100 1075 1150 3150 5200
Metdanol 100 1175 1250 3450 5750
Variable Temp. Experiments
(VT charges) + charges for each measurement as above at each temperature
Additional /hr 100 100 200 400 600
Solid state 1st hr 1000 1000 1500 2500 4000
Solid state Additional charges/hr 500 750 1000 1500 2000
              ^Deuterated solvents provided by user
# 19F, 31P, 27Al, 11B, 77Se, 125Te, 95Mo, 29Si measurements also will be done at same charges

• For solid state NMR analysis, sample details must be provided.
• If TMS spike is required, additional cost of Rs.50/- to be added.
• Sample details such as solubility, stability/degradation possibilities should be disclosed at tde time of submission of tde sample. tde centre will not be responsible for any wrong data obtained due to tde degradation of sample.
• Sufficient quantity of tde sample should be made available for analysis.
• Analysis and in-deptd interpretation of tde results are not included in tde above charges.
• Such services shall be provided on a consultation basis. For furtder details, contact tde Faculty-In-Charge.
• All users who wish to avail tde facility need to book tde slot well in advance.
• All investigators are expected to acknowledge tde services of tde centre in publications and similar articles.